Practical Aspects Of Routine Geotechnical Site Investigations � They Should Be Anything But Boring!
It�s likely that on any given day there are hundreds of geotechnical site investigations in progress in North America alone. While many of these investigations are carried out in support of large projects,...

What�ll They Think of Next? Dewatering Contaminated Slurries Using Geotextile Tubes
Sediment must be dredged from the bottom of waterbodies to maintain their capacity and navigability. Dredging, by its nature, involves the removal of highwater-content slurries and also helps preserve...

Sediment Pollution: Solving "Rill" Problems Using RECPs
Sediment pollution causes an estimated $16 billion in environmental damage annually. Sediment is the most common pollutant in rivers, streams, lakes, and reservoirs, causing such negative effects as temperature...

Megaproject Monitoring by Satellite ? InSAR-based Settlement-time History: Measuring Hundreds of Thousands of Points, Several Times a Month, Across an Entire City
Satellite-based interferometric synthetic aperture radar, or InSAR, has gained unequivocal importance as a routine and precise monitoring method for large and small areas alike. Historical datasets allow...

Tsunami Loads and Effects
Guide to the Tsunami Design Provisions of ASCE 7-16
The devastating tsunamis that struck Chile and Japan in 2010 and 2011 underscored the critical need for new structural design criteria to improve building resilience and safeguard human life. They also...

Spin, Spin, Spin
A scalable, vertical axis windmill tower with dynamic shutters that decrease wind loading on the structure has won an energy efficiency design contest....

Calibration of Jackup Leg Foundation Model Using Full-Scale Structural Measurements
The fitness of jack-up rigs to operate in varying water depths and weather conditions is determined by "site-specific" structural assessments. These assessments are conducted by a wide range of companies...

Pervious Concrete
Pervious concrete consists of a hydraulic cementitious binding system combined with an open-graded aggregate to produce a rigid pavement with typically 15% to 25% interconnected void space....

Maintenance
While site selection and proper construction are the most critical factors in establishing that permeable pavements function as designed, all must be inspected and maintained to maximize...

Loading, Geometry, and Analysis
This Standard applies to latticed steel transmission structures. These structures shall be either self-supporting or guyed. They consist of hot-rolled or cold-formed prismatic members...

Design of Connections
Bolted connections for transmission structures are normally designed as bearing type connections. It is assumed that bolts connecting one member to another carry the load in the connection...

Pipe Characteristics
Microtunneling pipe should meet the following general requirements: Circular shape with a flush outside surface (including at the joints); Strength sufficient to withstand both the installation...

Pipe Design
The pipes and joints, once installed, must be capable of safely withstanding, for the project design life, all in-use service loads, including those associated with the following factors:...

Findings From a Joint Industry Study on Foundation Fixity of Jackup Units
During the design storm conditions the soil supporting jack-up unit footings may be close to, or at plastic failure. Accordingly, the use of elastic solutions to the problems of foundation...

Performance Limits for Deepwater Pipelines
This paper highlights the differences between onshore and offshore pipeline design. It then summarizes the results of combined external pressure, tension, and bending testing on full scale...

Extreme Wave-Force Calculation Procedure for 20th Edition of API RP-2A
The paper describes the revised guideline design wave force calculation procedure approved for the 20th edition of the API-RP2A WSD and the first edition of the API-RP2A LRFD and contrasts...

A Simple Model to Predict Soil Resistance to Driving for Long Piles in Deepwater Normally Consolidated Clays
As the exploration and development for offshore oil and gas reserves moves into the deepwater environment of the continental slope, a good model is necessary to evaluate drivability of...

Radial Flow Consolidation Testing
A radial flow consolidation cell that can be used with commercially available loading frames was developed and a series of tests were performed on samples of sedimented kaolin. Simple...

Axial Load Capacity of Pipe Piles in Sands
The axial load capacity of driven, open-ended, steel pipe piles in cohesionless soils, is often estimated using a method such as the American Petroleum Institute Recommended Practice 2A...

Behaviour of Open-Ended Pipe Piles in Sand During Installation and Loading
An experimental study was performed to investigate the physical processes which influence the axial load capacities of open-ended steel pipe piles in sand. A double-walled pipe pile was...

 

 

 

 